DE NEEF® Soil PURe

Product Description

Soil PURe is a hydrophobic polyurethane that, when used alone or with Soil Cat PURe, is designed to increase the bearing capacity of permeable soil. In its uncured form, Soil PURe is a blackish-brown nonflammable liquid. When it comes in contact with water, the grout slightly expands and, depending on temperature and amount of accelerator (Soil Cat PURe) used, quickly cures to a very dense open cell foam that is essentially unaffected by corrosive environments and micro organisms.

Product Advantages

  • Free Foam Expansion up to 3 times
  • Contains no volatile solvents
  • Very high strength with no creep 
  • Very low viscosity for permeation into tight soils
  • Controlled reaction time

Product Applications

  • Stabilizing soil beneath slabs and roadways
  • Confinement of hazardous materials in soil
  • Creating below grade cut-off curtain wall

Packaging & Handling

Soil PURe:

5 gallon metal pail
50 gallon metal drum

Soil Cat PURe:

25 oz. metal cans

Soil PURe is sealed under dry nitrogen because it is sensitive to moisture, and should be stored in original containers in a dry area. Storage temperature must be between 40°F and 90°F. Once the packaging has been opened, the useful life of the material is greatly reduced and should be used as soon as possible.

Shelf life: 2 years.

Properties

SOIL PURE RESIN    
Solids 100% ASTM D2369
Viscosity 50 cp at 77°F ASTM D2196
Color Black-brown liquid  
Density 1.12 g/cm3 ASTM D4659
Flashpoint 284°F ASTM D93
Corrosiveness Non-corrosive  
Soil Cat PURe    
Viscosity 15 cp at 77°F ASTM D2196
Color Clear liquid  
Flashpoint 221°F ASTM D93
Soil PURe Cured    
Density confined 1.00 g/cm3 ASTM D3574
Compressive strength 1813 psi confined w/sand
Flexural strength 290 psi confined w/sand

Reaction Times

T % CAT END REACTION  FOAM FACTOR
40°F 0.5
1.0
1.5
2.0
2.5
14’30”
6’30”
5’00”
4’10”
2’46”
1V
2V
3V
3V
3V
50°F 0.5
1.0
1.5
2.0
2.5
12’06”
5’30”
4’30”
3’40”
2’40”
1V
2V
3V
3V
3V
60°F 0.5
1.0
1.5
2.0
2.5
11’30”
5’00”
4’00”
3’10”
2’30”
1V
2V
3V
3V
3V
68°F 0.5
1.0
1.5
2.0
2.5
10’50”
4’50”
3’50”
2’50”
2’20”
1V
2V
3V
3V
3V
77°F 0.5
1.0
1.5
2.0
2.5
8’46”
4’30”
3’25”
2’30”
2’06”
3V
3V
3V
3V
3V
86°F 0.5
1.0
1.5
2.0
2.5
8’00”
4’20”
3’05”
2’20”
2’00”
3V
3V
3V
3V
3V
95°F 0.5
1.0
1.5
2.0
2.5
7’35”
3’50”
3’05”
2’10”
1’56”
3V
3V
3V
3V
3V

Health and Safety

Always use protective clothing, gloves and goggles consistent with OSHA regulations during use. Avoid eye and skin contact. Do not ingest. Refer to Safety Data Sheet (SDS) for detailed safety precautions. SDS’s can be obtained from GCP Applied Technologies or from our web site at gcpat.com. For emergencies, call CHEMTREC 1-800-424-9300.

Installation Guidelines

Warning: Consult the Technical Data Sheets and SDS before using.

Installation Instructions: For detailed installation instructions refer to the DE NEEF® technical bulletin for your application.

Catalyst: Shake catalyst can 2-3 minutes. Pour the desired amount of Soil PURe into a clean dry pail. Measure the appropriate amount of Soil Cat PURe (refer to the Reaction Times section of this data sheet for the desired set time) and pour it into the pail. Stir until adequately mixed.

Injection: During injection the grout will follow the path of least resistance. When the material has stopped penetrating it will continue to expand against the limits of the confined space.

Extreme conditions: For application procedures in extreme temperatures and specific environments or equipment recommendations call DE NEEF® Technical Service.

Cleaning: Clean all tools and equipment which have been in contact with the resin with DE NEEF® Washing Agent before resin has cured. Products should be disposed of according to local, state, and federal laws.

Limitations

Low temperatures will significantly affect viscosity. If site temperatures are extremely low, heat bands or heated water baths may be used on the pails before and during installation to maintain the product’s temperature. Avoid splashing water into open containers, as the material is water activated. Avoid exceeding 90˚F when warming.

CAUTION: pH NOTICE. Water used to activate PURe Grouts must be in the pH range of 3-10 for optimum foam quality

ca.gcpat.com | North America customer service: 1-877-4AD-MIX (1-877-423-6491)

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

DE NEEF is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.

© Copyright 2018 GCP Applied Technologies Inc. All rights reserved.

GCP Applied Technologies Inc., 62 Whittemore Avenue, Cambridge, MA 02140 USA.

In Canada, GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6.

Ce document est à jour seulement à la date de la dernière mise à jour indiquée ci-dessous et n'est valide que pour une utilisation au Canada. Il est important que vous consultiez toujours les informations actuellement disponibles sur l'URL ci-dessous pour fournir les informations les plus récentes sur le produit au moment de l'utilisation. Des documents supplémentaires tels que les manuels de l'entrepreneur, les bulletins techniques, les dessins détaillés et les recommandations détaillées ainsi que d'autres documents pertinents sont également disponibles sur www.ca.gcpat.com. Les informations trouvées sur d'autres sites Web ne doivent pas être utilisées, car elles peuvent ne pas être à jour ou applicables aux conditions de votre site et nous déclinons toute responsabilité quant à leur contenu. S'il y a des conflits ou si vous avez besoin de plus d'informations, veuillez contacter le service client de GCP.

Last Updated: 2018-12-12

https://ca.gcpat.com/en/solutions/products/de-neef-waterproofing-injection-solutions/de-neef-soil-pure