PERM-A-BARRIER® Detail Membrane
Self-adhesive, rubberized asphalt/polyethylene detail membrane for air and vapor barrier applications
Product Description
PERM-A-BARRIER® Detail Membrane is ideal for protecting and sealing critical areas of the building superstructure from the damaging effects of the elements. By minimizing air and water vapor flow through the building exterior at transition areas, PERM-A-BARRIER® Detail Membrane:
- Seals transition and detail areas to provide a continuous air barrier
- Prevents premature deterioration of the building envelope
Product Advantages
- Fully bonded - transmits wind loads directly to the substrate
- Waterproof and impermeable to moisture - impermeable to the passage of liquid water and water vapor
- Air tight - exceeds CCMC requirements for air barrier membranes, complies with Massachusetts State Energy Code
- Cross laminated film - provides dimensional stability, high tear strength, puncture and impact resistance
- Cold applied - no flame hazard; self-adhesive overlaps ensure continuity
- Flexible - accommodates minor settlement and shrinkage movement
- Controlled thickness - factory made sheet ensures constant, non-variable site application
- Aggressive, conformable adhesive - allows self-sealing around mechanical fasteners
- Wide application window - PERM-A-BARRIER® Detail Membrane surface and ambient temperatures at 25°F (-4°C) and above
System Components
- PERM-A-BARRIER® Detail Membrane - fully adhered flashing for protecting and sealing critical detail areas
- PERM-A-BARRIER® WB Primer - high tack, water-based primer for use with PERM-A-BARRIER® Detail Membrane on cementitious and exterior gypsum wallboards
- BITUTHENE® Primer B2 LVC - low VOC primer used to prime green concrete or damp surfaces
- PERM-A-BARRIER® Universal Flashing & Sealant - one part moisture curing, STPE sealant for sealing penetrations, terminations, brick ties, final terminations & flashing application. PERM-A-BARRIER® Universal Flashing & Sealant can be applied under all GCP air and weather barrier, and over most of them (limitation: PERM-A-BARRIER® VPS 30).
- BITUTHENE® Mastic Trowel Grade - rubberized asphalt mastic for sealing patches, terminations, brick ties, etc.
- BITUTHENE® Liquid Membrane - two component, trowel grade, asphalt modified urethane for sealing patches, terminations, brick ties, etc.
Installation
Safety
PERM-A-BARRIER® products must be handled properly. Vapors from the mastic and solvent-based primer are harmful and flammable. For these products, the best available information on safe handling, storage, personal protection, health and environmental considerations has been gathered. Refer to product label and SDS (Safety Data Sheet) before use. All users should acquaint themselves with this information prior to working with the material. Carefully read detailed precaution statements on the product labels and SDS before use. SDSs can be obtained from our web site at gcpat.com or by contacting us toll free at 866-333-3SBM (3726).
Surface Preparation
Surface must be smooth, clean, dry and free of voids, spalled areas, loose aggregate, loose nails, sharp protrusions or other matter that will hinder the adhesion or regularity of the wall membrane installation. Clean loose dust or dirt from the surface to which the detail membrane is to be applied by wiping with a clean, dry cloth or brush.
If the substrate is damp, allow to dry or use BITUTHENE® Primer B2 LVC to prepare the area to receive the membrane. DO NOT apply any primer to PERM-A-BARRIER® Detail Membrane.
Temperature
PERM-A-BARRIER® Detail Membrane may only be applied in dry weather when air and surface temperatures are above 25°F (-4°C).
Application
Priming - PERM-A-BARRIER® Primer® Plus and PERM-A-BARRIER® WB Primer are water-based primers which impart an aggressive, high tack finish on the treated substrate. They are packaged ready to use and are specifically designed to facilitate tenacious adhesion of PERM-A-BARRIER® Detail Membrane to various substrates including glass-mat faced gypsum sheathing. Refer to Technical Letter 2, Substrate Preparation for Application of PERM-A-BARRIER® Products to Glass-Mat Faced Gypsum Sheathing for priming requirements on specific glass-mat faced sheathing products.
Detail Membrane Application - Pre-cut PERM-A-BARRIER® Detail Membrane to easily handled lengths. Peel release paper from roll to expose rubberized asphalt and carefully position tape against substrate. Press firmly into place with a steel hand roller or the back of a utility knife as soon as possible, fully adhering the tape to the substrate to prevent water from migrating under the PERM-A-BARRIER® Detail Membrane. Overlap adjacent pieces 2 in. (51 mm) and roll overlap with a steel hand roller.
When applying PERM-A-BARRIER® Detail Membrane to PERM-A-BARRIER® Wall Membranes and PERM-A-BARRIER® Wall Flashing - Apply a bead of Universal Flashing & Sealant, BITUTHENE® Mastic or BITUTHENE® Liquid Membrane along top edges, cuts, penetrations, all laps and seams on horizontal surfaces (e.g. sill plates), critical areas and as shown in GCP detail drawings, and trowel into place.
When applying PERM-A-BARRIER® Detail Membrane to PERM-A-BARRIER® Liquid, PERM-A-BARRIER® VP, PERM-A-BARRIER® VP Low Temp or PERM-A-BARRIER® VPO - Apply a bead of Universal Flashing & Sealant or BITUTHENE® Liquid Membrane along top edges, cuts, penetrations, all laps and seams on horizontal surfaces (e.g. sill plates), critical areas and as shown in GCP detail drawings, and trowel into place. If PERM-A-BARRIER® Liquid is more than 7 days old, priming may be necessary. Refer to Technical Letter 11 for more information.
No reglet is necessary when installing PERM-A-BARRIER® Detail Membrane to vertical surfaces. Complete installation instructions and details are available upon request.
If wrinkles develop, carefully cut out affected area and replace in similar procedure outlined above. The repair piece must be pressed into place with a hand roller as soon as possible to ensure continuous and intimate contact with the substrate.
All non water shedding edges must be sealed with Universal Flashing & Sealant, BITUTHENE® Liquid Membrane or BITUTHENE® Mastic.
Membrane Protection
PERM-A-BARRIER® Detail Membrane must be protected from damage by other trades or construction materials.
Storage and Handling Information
All materials must be protected from rain and physical damage. Pallets of PERM-A-BARRIER® Wall Membrane must not be double stacked on the job site. Provide cover on top and all sides, allowing for adequate ventilation. Store membrane where temperatures will not exceed 90°F (32°C) for extended periods. All products must be stored in a dry area away from high heat, flames or sparks. Store only as much material at point of use as is required for each day’s work.
Limitations
PERM-A-BARRIER® Membrane systems must not be applied in areas where they will be permanently exposed to UV light and must be covered within a reasonable amount of time, not to exceed 60 days. Refer to Technical Letter 19, Exposure Guidelines for PERM-A-BARRIER® Self-Adhered Membranes.
Warranty
PERM-A-BARRIER® products are warranted to be free of defects in manufacture for a period of 5 years. Material will be provided at no charge to replace any defective product.
Technical Service
Support is provided by full-time technically trained GCP field sales representatives and technical service personnel, backed by a central research and development technical services staff.
Supply
Unit of Sale | Approximate Coverage | Weight | Palletization | |
---|---|---|---|---|
PERM-A-BARRIER® Detail Membrane | ||||
6 in. (152 mm) 9 in. (225 mm) 12 in. (305 mm) | 6 rolls 4 rolls 3 rolls | 75 linear ft per roll 75 linear ft per roll 75 linear ft per roll | 11 lbs/roll 16 lbs/roll 22 lbs/roll | 25 cartons (150 rolls) per pallet 25 cartons (100 rolls) per pallet 25 cartons (75 rolls) per pallet |
BITUTHENE® Mastic - 5 gal pail | 1 pail | approx. 120 ft2 at 60 mils | 54 lbs/pail | 36 pails per pallet |
BITUTHENE® Mastic - 30 oz tube | 12 tubes | approx. 30 linear ft x 1/4 in. bead | 32 lbs/carton | 72 cartons (864 tubes) per pallet |
PERM-A-BARRIER® Universal Flashing & Sealant - 29 oz. Cartridge | 1 cartridge | approx. 30 linear ft x 1/4 1/4 in. bead | 29 oz. cartridge | 10 cartridges/ carton 42 cartons/ pallet |
BITUTHENE® Liquid Membrane - 1.5 gal pail | 1 pail | approx. 200 Linear ft/gal @ 1” wide x 90 mils. | 16 lbs/pail | 100 pails per pallet |
BITUTHENE® Liquid Membrane - 4 gal pail | 1 pail | approx. 200 Linear ft/gal @ 1” wide x 90 mils. | 44 lbs/pail | 24 pails per pallet |
PERM-A-BARRIER® WB Primer - 5 gal pail | 1 pail | 250–350 ft2/gal (6–8 m2/L) | 45 lbs | 32 pails per pallet |
BITUTHENE® Primer B2 LVC - 5 gal pail | 1 pail | 325–425 ft2/gal (7.5–10 m2/L) | 44 lbs/pail | 48 pails per pallet |
Physical Properties
PERM-A-BARRIER® Detail Membrane | Test Method | |
---|---|---|
Thickness | 3/64 in. (1 mm) | ASTM D3767 method A |
Minimum tensile strength, membranes | 400 psi (2.8 MPa) | ASTM D412 die C modified |
Minimum tensile strength, film | 5000 psi (34.5 MPa) | ASTM D412 die C modified |
Minimum elongation, to failure of rubberized asphalt | 200% | ASTM D412 die C modified |
Pliability, at 180° bend over 1 in. (25 mm) mandre | Pass at -25 °F (-32 °C) | ASTM D1970 |
Crack cycling, 1/8 in. (3.2 mm) at -25 °F (-32 °C) | Unaffected | ASTM C836 |
Minimum puncture resistance, membrane | 40 lbs (178 N) | ASTM E154 |
Lap peel adhesion at minimum application temperature | 4 lbs/in. (700 N/m width) | ASTM D1876 modified |
Maximum permeance to water vapor transmission | 0.05 perms/(Pa.s.m2) (2.9 ng) | ASTM E96 method B |
Air permeance1 | 0.0002 cf/min/ft2 (<0.001 L/s/m2) | ASTM E2178 |
Air permeance of in-place membrane2 | No change in air permeance value | ASTM E330 |
Water absorption (weight gain at 24 hours) | 0.1% | ASTM D570 |
Footnote:
1. Air permeance measured at a pressure differential of 1/64 in. (68 Pa) Hg.
2. Air permeance measured at a pressure differential of 1/64 in. (68 Pa) Hg after wall being subjected to a negative 57/64 in. (3014 Pa) Hg pressure difference for 10 seconds.
ca.gcpat.com | North America customer service: 1-877-4AD-MIX (1-877-423-6491)
We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation or suggestion is intended for any use that would infringe any patent, copyright or other third-party right.
BITUTHENE and PERM-A-BARRIER are trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies, Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.
© Copyright 2018 GCP Applied Technologies, Inc. All rights reserved.
GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 475, Alpharetta, GA 30009, USA
GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6.
This document is only current as of the last updated date stated below and is valid only for use in the Canada. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.
Last Updated: 2024-09-05
https://ca.gcpat.com/en/solutions/products/perm-a-barrier-air-barrier-system/perm-a-barrier-detail-membrane