SINTA® M2219 Synthetic Fibers
Synthetic Micro Fiber for reinforcement of concrete (formerly Grace Microfiber™)
Product Description
SINTA® M2219 is a synthetic fiber for concrete, manufactured from 100% virgin polypropylene in a micro-monofilament form. SINTA® M2219 is produced on a state-of-the-art production line which is specifically designed to yield an ultrathin concrete reinforcing fiber able to achieve superior performance at a lower dosage rate compared to conventional monofilament fibers. SINTA® M2219 contains over 70 million individual fibers for each 1.0 lb/yd3 dosed. Engineered specifically for use in concrete, they are alkali resistant, non-absorptive and completely non-corrosive. SINTA® M2219 protects concrete from stresses which cause cracking while the concrete is most vulnerable during the first 24 hours after placement. SINTA® M2219 complies with ASTM Designation C1116, Standard Specification for Fiber-Reinforced Concrete and Shotcrete, Type III Synthetic Fiber-Reinforced Concrete or Shotcrete. SINTA® M2219 is available in 0.75 in. (19 mm) length.
Compliance and Certification
- ASTM C1116 / C1116M, Standard Specification for Fiber-Reinforced Concrete, Type III Synthetic Fiber-Reinforced Concrete
- Meets ICC ES AC32 criteria for Plastic Shrinkage Crack Reduction
Product Advantages
SINTA® M2219 uniformly distributes multi-dimensionally through-out the concrete mixture. The extremely high number of fibers in the fresh concrete matrix protects the concrete when its tensile strength is lowest, reducing the formation of plastic shrinkage cracking. The reinforcement reduces the formation of all types of early age cracking. This cracking caused by plastic shrinkage, settlement and other internal stresses would otherwise permanently weaken the resultant concrete. This cracking and other internal stresses would otherwise permanently weaken the resulting concrete. The concrete permeability is decreased, while surface characteristics, impact and toughness properties are improved.
When tested in accordance with ICC ES AC32 criteria for plastic shrinkage crack reduction, SINTA® M2219 fibers provided a 78% reduction in plastic shrinkage cracking over a control sample when dosed at 0.5 pcy.
Technically advanced production techniques make SINTA® M2219 a highly durable fiber that is virtually invisible in fresh concrete. This minimizes fiber-reinforced concrete finishing concerns while providing the highest level of crack protection available.
- Protects concrete when tensile strength is at its lowest, reducing the formation of plastic shrinkage cracking.
- Enhances impact and toughness properties.
- Easy to mix and fast to disperse.
- Minimizes fiber-reinforced concrete finishing concerns.
- Reduces plastic shrinkage cracking and improves durability.
- Protects concrete from stresses that cause cracking.
- Provides cost effective control of plastic shrinkage.
- Provides overall higher quality of concrete.
Uses
SINTA® M2219 may be used as an alternative to light-gage welded-wire reinforcement in applications where decreased plastic shrinkage cracking and improved durability are desired.
Specifically, such applications include but are not limited to, slabs on grade, pavements, overlays, sloped walls, pools, shotcrete, stucco, precast and prestressed products. It is suggested that this product be used in conjunction with properly compacted base materials and jointing in accordance with ACI guidelines and standards.
Addition Rates
SINTA® M2219 may be added to concrete at any point during the batching or mixing process. SINTA® M2219 may be added to the aggregate during weighing or charging, or to the central mixer or truck before, during, or after charging. The concrete must be mixed at high speed for 5 minutes, or 70 revolutions, after the addition of SINTA® M2219 to ensure uniform distribution. The standard range of addition for SINTA® M2219 is 0.5 to 1.0 lb/yd3 (300 to 600 g/m3) of concrete. ASTM C1579 testing has shown that 0.5 lb/yd3 (300 g/m3) is most efficient, providing greater than 77% crack reduction when compared to the control specimen.
Compatibility with Other Admixtures
SINTA® M2219 is compatible with all GCP admixtures. Its action in concrete is purely mechanical and will not affect the hydration process. Each admixture should be added separately.
SINTA® M2219 Physical Properties
Specific gravity | 0.91 |
Absorption | None |
Modulus of elasticity | 500 ksi (3.45 GPa) |
Tensile Strength | 42 ksi (290 MPa) |
Melt point | 320°F (160°C) |
Ignition point | 1094°F (590°C) |
Alkali, acid and salt resistance | High |
Material | 100% virgin polypropylene |
Nominal Length | 0.75 in. (19 mm) |
Nominal Fiber Count | 70 million per lb. |
Specifications
Fibers shall be 0.75 in. (19 mm) micro-monofilament polypropylene fibers as supplied by GCP Applied Technologies, 62 Whittemore Ave., Cambridge, MA 02140. One pound (450 grams) of fibers shall contain no less than 70 million individual fibers, 0.5 lb (225 grams) of fibers shall contain no less than 35 million individual fibers. Required dosage rate shall be as specified by the design engineer or architect. SINTA® M2219 shall be used in strict accordance with the supplier’s recommendations and within time as specified in ASTM C94. The fiber shall comply with ASTM Designation C1116 Type III. Standard ACI 302 procedures for placing, finishing and curing shall be followed when using SINTA® M2219.
Packaging
SINTA® M2219 is available in convenient Concrete-Ready® Bags which are added, unopened, to the truck drum or central mixer. The specially designed cellulose fiber bags disintegrate and disperse the fibers throughout the mix. SINTA® M2219 is available in 0.5 lb and 1.0 lb Concrete-Ready™ Bags in the U.S. and 600 g Concrete-Ready™ Bags in Canada.
Safety and Handling
Read and understand the product label and Safety Data Sheet (SDS). All users should acquaint themselves with this information prior to working with the products and follow the precautionary statements. SDSs can be obtained by contacting your local GCP representative or office.
References
Building Codes
BOCA National Building Codes, SBCCI Standard Building Code, ICBO Uniform Building Code and all supplements as adopted by the Council of American Building Officials.
American Concrete Institute (ACI)
ACI 544.1 R State of the Art Report of Fiber-Reinforced Concrete
ACI 302 Guide for Concrete Floor and Slab Construction
American Society of Testing and Materials (ASTM)—
ASTM C1116 Standard Specification for Fiber-Reinforced Concrete and Shotcrete.
ASTM C1579 Standard Test Method for Evaluating Plastic Shrinkage Cracking of Restrained Fiber Reinforced Concrete (Using a Steel Form Insert).
ASTM C94 Standard Specification for Ready-Mixed Concrete.
ca.gcpat.com | North America customer service: 1-877-4AD-MIX (1-877-423-6491)
We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.
SINTA, STRUX, and MicroFiber are trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.
© Copyright 2020 GCP Applied Technologies Inc. All rights reserved.
GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 475, Alpharetta, GA 30009, USA
GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6.
This document is only current as of the last updated date stated below and is valid only for use in the Canada. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.
Last Updated: 2024-06-21
https://ca.gcpat.com/en/solutions/products/sinta-f-fibers-sinta-m-fibers-and-sinta-fds/sinta-m2219-micro-fibre-synth-tique