Product Description
TYTRON® is a proprietary technology developed at the research laboratories of GCP. It represents a revolutionary new chemistry for use in the production of cement for masonry applications.
Designed to be interground during the cement manufacturing process, TYTRON® use allows cement manufacturers to achieve performance consistent with the requirements of ASTM C 91-95c Standard Specification for Masonry Cement. In addition, its use provides important performance benefits such as excellent workability, long board life, water repellency and superior water retention. TYTRON® is supplied in a stable solution so that storage and use in a variety of different conditions and climates is never a problem.
For special cases where extra performance is desired by the masonry manufacturer or user, the basic TYTRON® formulation can be modified to produce enhanced performance in the areas of workability, board life, water retention and/or strength. These additional benefits can essentially be added through “custom-designing” by GCP technical personnel to produce the TYTRON® S, TYTRON® A, TYTRON® R, TYTRON® P or Tytron W variants. Combinations of benefits may also be obtained through the use of such products as TYTRON® WA, TYTRON® SA, etc. as desired by the customer. Such custom formulations would typically require laboratory work by GCP, utilizing the customer’s raw materials, followed by a plant trial for formula optimization, with the ultimate goal being a product that is uniquely suited for the specific raw materials and performance requirements of the market.
Typical1 Performance Properties of the Tytron product line are shown below:
Product |
TYTRON® |
TYTRON® S |
TYTRON® A |
TYTRON® R |
TYTRON® P |
TYTRON® W |
TYTRON® WA |
---|
Additive Dosage (lb/ton) |
2.5-4.5 |
2.5-4.5 |
3.0-5.0 |
2.5-4.5 |
3.0-5.0 |
3.0-5.0 |
4.0-6.0 |
Setting Times (minutes) |
|
|
|
|
|
|
---|
Initial Set |
300 |
300 |
300 |
350 |
300 |
300 |
300 |
Final Set |
500 |
500 |
500 |
550 |
500 |
550 |
550 |
Water Retention (%) |
80+ |
80+ |
80++ |
80+ |
80+ |
80++ |
80++ |
Board Life |
|
|
|
|
|
|
|
---|
Initial Downgrade |
60 |
75 |
90 |
90 |
75 |
90 |
90 |
Final Downgrade |
75 |
105 |
120 |
120 |
105 |
120 |
120 |
Air Entrainment % (max) |
19-21 |
19-21 |
19-21 |
19-21 |
19-21 |
19-21 |
19-21 |
Formulation Advantages |
Lowest Cost |
Strength |
Water Retention Board Life |
False Set Control Board Life |
Workability Water Repellency |
Workability Water Retention Board Life |
Water Retention Workability Board Life |
Notes: 1 Performance shown here is meant to suggest a typical value. Due to GCP’s custom formulating capabilities and varying cement raw material characteristics, actual performance could exceed the values listed above.